4 drive control word – Vector 6SE70 VC User Manual

Page 29

Advertising
background image

Version 1.0 March 1, 2000

Page 29

1.4 Drive Control Word

Function Diagrams will be referred to in brackets with their number. Please refer to
function diagrams in the compendium. Example [Diagram Number]

Assign Digital Inputs

Assign Off2(Coast Stop)

Assign Off3(Quick Stop)

Assign ON/OFF1

[180] Assign Other
Functionality as
Required

See [190]
Assign Other Control
Functionality as
Required

Digital Inputs/Outputs:
Binector Assignments for Control
may be made from Digital Inputs

P555, P556 & P557 can be used
to assign Coast to Stop

P558, P559 & P560 can be used
to assign Quick Stop

P554 MUST be assigned to
activate drive. Note:
Acceleration and Deceleration
will be based on ramp generator
[320]

Advertising