Ab c d – Vector 6SE70 VC User Manual

Page 51

Advertising
background image

Version 1.0 March 1, 2000

Page 51

A

D

C

B

Select Record Settings in
the Lower Left Corner

Select Desired Channels
to Record

Set the Record Interval
and Pre-trigger

Select Trigger Channel

To Trigger With a Binector, Select:
Trigger Channel = K431
Trigger Condition “=” “1 Hex”

K431 is the output of a Binector to
Connector Converter that will be
configured on the following page.

A

B

C

D

Each Interval = (4.0 / P340) seconds.