2 of 5 is so susceptible to misreads that the RF Terminal adds an additional safeguard - it can be configured to

look for fixed-length data only.

The default setting of 06 causes the RF Terminal to read only 2 of 5 codes that are 6 digits in length. To set

the RF Terminal to read a different length, enter any two-digit number. 2 of 5 code must always be an even
number of digits so the length setting must always be an even number.

Reading variable length I 2of5 or 2 of 5 codes is to be avoided if at all possible. The 00 setting is supplied for

the purposes of reading codes of unknown length, counting the digits and setting the length to the proper
number.

MSI and Plessey

MSI/Plessey

ON

OFF

1

MSI/Plessey-Single Mod 10 Check Digit

ON

OFF

1

MSI/Plessey-Double Mod 10 Check Digit

ON

OFF

1

MSI/Plessey-Single Mod 11/Single Mod 10
Check

ON

OFF

1

Enable Plessey / Disable MSI

ON

OFF

1

Transmit Check Digits

0, 1 or 2

2

The MSI/Plessey options are selected by pressing the 1 key to select the desired mode of operation.

If you have enabled the Mod 10 or Mod 11 check digits, they will be transmitted along with your bar code

data from the RF Terminal to your host.

For more information regarding MSI or Plessey Code, see Appendix K; MSI Plessey Code.

Code 93 / Code 11

Code 93

ON

OFF

1

Code 93 Full ASCII

ON

OFF

2

Code 11

ON

OFF

3

Code 11 Check Digit Transmission

0, 1 or 2

4

Code 93 is similar in character set to Code 39. See Appendix F; Code 93 for more information. Code 93 is not a

commonly used bar code symbology.

DataBar / RSS-14 Options

DataBar / RSS-14

ON

OFF

1

DataBar / RSS-14 plus Identifiers

ON

OFF

1

DataBar / RSS-14 plus UCC-128 Format

ON

OFF

1

By default, DataBar / RSS-14 is disabled. Press the 1 key to toggle through the DataBar / RSS-14 options listed
above. We support the standard and stacked version of DataBar / RSS-14.

For more information on GS1 DataBar, see the GS1.org website at

http://www.gs1.org/productssolutions/barcodes/databar/