Internal sptgen, Appendix k internal sptgen, Internal sptgen overview – ZyXEL Communications P-2602HW(L) Series User Manual

Page 395: The configuration text file format

Advertising
background image

P-2602H(W)(L)-DxA Series User’s Guide

Appendix K Internal SPTGEN

395

A

P P E N D I X

K

Internal SPTGEN

Internal SPTGEN Overview

Internal SPTGEN (System Parameter Table Generator) is a configuration text file useful for
efficient configuration of multiple ZyXEL Devices. Internal SPTGEN lets you configure, save
and upload multiple menus at the same time using just one configuration text file – eliminating
the need to navigate and configure individual screens for each ZyXEL Device.

The Configuration Text File Format

All Internal SPTGEN text files conform to the following format:

<field identification number = field name = parameter values
allowed = input>,

where <

input

> is your input conforming to <

parameter values allowed

>.

The figure shown next is an example of an Internal SPTGEN text file.

Figure 224 Configuration Text File Format: Column Descriptions

Note: DO NOT alter or delete any field except parameters in the Input column.

This appendix introduces Internal SPTGEN. All menus shown in this appendix are example
menus meant to show SPTGEN usage. Actual menus for your product may differ.

Internal SPTGEN File Modification - Important Points to Remember

Each parameter you enter must be preceded by one “=”sign and one space.

/ Menu 1 General Setup

10000000 = Configured <0(No)| 1(Yes)> = 1

10000001 = System Name <Str> = Your Device

10000002 = Location <Str> =

10000003 = Contact Person’s Name <Str> =

10000004 = Route IP <0(No)| 1(Yes)> = 1

10000005 = Route IPX <0(No)| 1(Yes)> = 0

10000006 = Bridge <0(No)| 1(Yes)> = 0