ZyXEL Communications P-2602HW(L) Series User Manual

Page 210

Advertising
background image

P-2602H(W)(L)-DxA Series User’s Guide

210

Chapter 14 Firewall Configuration

Maximum

Incomplete Low

This is the number of existing half-open

sessions that causes the firewall to stop

deleting half-open sessions. The ZyXEL

Device continues to delete half-open requests

as necessary, until the number of existing

half-open sessions drops below this number.

80 existing half-open sessions.

Maximum

Incomplete High

This is the number of existing half-open

sessions that causes the firewall to start

deleting half-open sessions. When the

number of existing half-open sessions rises

above this number, the ZyXEL Device deletes

half-open sessions as required to

accommodate new connection requests. Do

not set Maximum Incomplete High to lower

than the current Maximum Incomplete Low

number.

100 existing half-open sessions.

The above values causes the

ZyXEL Device to start deleting half-

open sessions when the number of

existing half-open sessions rises

above 100, and to stop deleting

half-open sessions with the

number of existing half-open

sessions drops below 80.

TCP Maximum

Incomplete

This is the number of existing half-open TCP

sessions with the same destination host IP

address that causes the firewall to start

dropping half-open sessions to that same

destination host IP address. Enter a number

between 1 and 256. As a general rule, you

should choose a smaller number for a smaller

network, a slower system or limited

bandwidth.

30 existing half-open TCP

sessions.

Action taken when the TCP Maximum Incomplete reached threshold

Delete the Oldest

Half Open Session

when New

Connection

Request Comes.

Select this radio button to clear the oldest half

open session when a new connection request

comes.

Deny New

Connection

Request for

Select this radio button and specify for how

long the ZyXEL Device should block new

connection requests when TCP Maximum

Incomplete is reached.
Enter the length of blocking time in minutes

(between 1 and 256).

Apply

Click Apply to save your changes back to the ZyXEL Device.

Cancel

Click Cancel to begin configuring this screen afresh.

Table 75 Firewall: Threshold (continued)

LABEL

DESCRIPTION

DEFAULT VALUES