Automatic setup – Yamaha RX-Z7 User Manual

Page 145

Advertising
background image

145

En

Troubleshooting

AD

DITIONAL

INFO

RMA

T

ION

Automatic setup

Before automatic setup

During automatic setup

Error message

Cause

Remedy

See

page

Connect MIC!

Optimizer microphone is not connected.

Connect the supplied optimizer microphone
to the OPTIMIZER MIC jack on the front
panel.

35

Unplug Phones!

Headphones are connected.

Unplug the headphones.

Select Setup Item!

No check items are selected as the
measurement items.

Select the desired check items.

36

Memory Guard!

The parameters of this unit are protected.

Set “Memory Guard” to “Off”.

105

Error message

Cause

Remedy

See

page

E01:No Front SP

Front L/R channel signals are not detected.

Check the front L/R speaker connections.

17

E02:No Sur. SP

A surround channel signal is not detected.

Check the surround speaker connections.

17

E03:No PRNS SP

A presence channel signal is not detected.

Check the presence speaker connections.

17

E04:SBR

SBL

Only right surround back channel signal is
detected.

Connect the surround back speaker to the
SURROUND BACK (SINGLE) speaker
terminal if you only have one surround
back speaker.

17

E05:Noisy

Background noise is too loud.

Perform the automatic setup in a quiet
environment.

Turn off noisy electric equipment like air
conditioners or move them away from the
optimizer microphone.

E06:Check Sur.

Surround back speakers are connected,
though surround L/R speakers are not.

Connect surround speakers when you use
surround back speakers.

18

E07:No MIC

The optimizer microphone was unplugged
during the “automatic setup” procedure.

Connect the supplied optimizer microphone
to the OPTIMIZER MIC jack on the front
panel.

35

E08:No Signal

The optimizer microphone does not detect
test tones.

Check the microphone setting.

35

Check the speaker connections and
placement.

17

The optimizer microphone or OPTIMIZER
MIC jack may be defective. Contact the
nearest Yamaha dealer or service center.

E09:User Cancel

The “automatic setup” procedure was
cancelled due to user activity.

Perform the automatic setup again.

35

E10:Internal Err.

An internal error occurred.

Perform the automatic setup again.

35

Advertising