Troubleshooting Reference

975-0057-01-01

5-3

AC appliance
will not
operate;
audible alarm
is sounding.

Battery has discharged
to 10.5 V.

Inverter has
overheated due to poor
ventilation or
excessively warm
environmental
conditions.

Turn the AC Outlet On/Off switch
off and recharge the

XPower

Powerpack

.

Turn the AC Outlet On/Off switch
off and allow the

XPower

Powerpack

to cool for 15 minutes or

more. Clear blocked fan opening or
remove objects covering the unit,
then restart the

XPower Powerpack

.

Move to a cooler environment.

Over-
temperature
shutdown

Inverter has
overheated due to poor
ventilation or
excessively warm
environmental
conditions.

Turn off the AC Outlet On/Off
switch, and let the

XPower

Powerpack

cool down.

Alarm sounds

Internal battery is
nearly discharged.
(11.0 V).
If you ignore this
warning, the

XPower

Powerpack

automatically switches
off when the battery
reaches 10.5 V.

Turn the AC outlet ON/OFF switch
OFF and recharge the

XPower

Powerpack

.

Run time is
less than
expected.

Internal battery is not
fully charged.

AC appliance power
consumption is higher
than expected.

Recharge using the AC Charger,
until green Charging Status light is
steady.

Check AC appliance power or
wattage rating (or current draw for
12 V DC appliances) and compare
with

Table 3-1 on page 3–5

and

Table 3-2 on page 3–9

.

Table 5-1 Troubleshooting reference