Xantrex Technology 200 User Manual

Page 66

Advertising
background image

Specifications

A-2

975-0057-01-01

AC Power Section

Output power
• Continuous output power
• Five minute AC output power
• AC output surge capacity

320 W
400 W
600 W

Output voltage

115 ± 10 V AC RMS

Output frequency

60 Hz ± 4 Hz

Output wave form

modified sinewave

No load current draw

<0.20 A DC

Input voltage range

10.5 to 15.0 V DC

Low battery alarm

11.0 V DC

Low battery shutdown

10.5 V DC

High battery voltage shutdown

Yes, automatic reset

Over temperature shutdown

Yes, automatic reset

Overload shutdown

Yes, automatic reset

AC output short circuit protection

Yes, automatic reset

Fuse (internal)

2 x 25 A or 1 x 50 A

Operating temperature range

32 – 104 ºF
(0 – 40 ºC)

Storage temperature range

32 – 86ºF
(0 – 30 ºC)

Internal Battery Charging Controller System

AC Charger bulk charging current

750 mA

Peak charging voltage (nominal)

14.2 V

Charge restart voltage (nominal)

12.9 V

Float charge after full charge is completed
(nominal)

1 mA

AC Charger input socket maximum current

2.5 A

Advertising