Displays only in NITROX Mode:

Oxygen%: 21 - 50

Oxygen partial pressure display: 1.2 - 1.6 bar depending on the limit

setting

Oxygen Limit Fraction: 1 - 110% with 10% resolution (bar graph)

Logbook/Dive Profi le Memory:

Recording interval: 20 seconds (the recording interval can be set to 10s,

30s or 60s with the optional PC-interface and its software), records the
maximum depth of each interval.

Memory capacity: approximately 36 hours of diving with 20 seconds

recording interval

Depth accuracy: 0.3 m [1 ft]

Operating Conditions

Normal altitude range: 0 to 3000 m [10000 ft] above sea level

Operating temperature: 0°C to 40°C [32°F to 104°F]

• Storage temperature: -20°C to +50°C [-4°F to +122°F]

It is recommended that the instrument be stored in a dry place at room

temperature.

NOTE! Do not leave the dive computer in direct sunlight!

Tissue Calculation Model

SUUNTO RGBM algorithm (developed by SUUNTO and Bruce R.

Wienke, BS, MS and PhD)

• 9 tissue compartments

Tissue compartment halftimes: 2.5, 5, 10, 20, 40, 80, 120, 240 and 480

minutes (on gassing). The off gassing halftimes are slowed down

• Reduced gradient (variable) “M” values based on diving habit and dive

violations. The “M” values are tracked up to 100 hours after a dive

The EAN and oxygen exposure calculations are based on recommenda-

tions by R.W. Hamilton, PhD and currently accepted exposure time
limit tables and principles