Tyco Electronics FOSC-400D5 User Manual

Page 15

Advertising
background image

12.3

Place the dome carefully over the trays

onto the base. Put the clamp around the
base/dome interface. Close the clamp.

13.1

Remove the clamp.

13.2

Remove carefully the dome and the sealing ring. Keep the sealing ring and seal area of the

closure free of dirt. (If needed rinse with clear water).

13.3

The dome may be reinstalled by following the procedure as described in section 9.

Replace the 75 grams of desiccant. The sealing ring has also to be replaced if damaged. A
new sealing ring and 75 gram of desiccant can be ordered: FOSC-D-O-RING-SEAL-KIT.

13

Re-entry

14

Cable installation in circular outlet

14.1

Open the port for cable entry by

cutting the port at the ridge with a hacksaw.
Deburr the inner edge of the port opening with
abrasive strip.

Advertising