14.7

Abrade port and cable sheath

circumferentially on the cleaned area with the
abrasive strip. Remove any abraded material
with a clean cloth.

14.8

Place cable seal over the drop outlet of

FOSC base. When cable seal butts against the
base, mark the sleeve length on cable sheath.

14.9

Match the blue line of the aluminium

cable protection foil with the marks on the
cables. Wrap the aluminium cable protection
foil around cable.

14.10

Slide the cable seal over the port and

shrink the cable sleeve on the base side with
the recommended hot air gun
device. Use the reflector to ensure heat
distribution around the outlet. Shrink sleeve
until the green thermo-indicating paint is
converted to black.
Note. Setting thermogun: FACC-HEAT-GUN -
220V in position 10. Minimum hot air
temperature should be 350°C.