2-5 Checking the Motherboard Setup

After you install the RMC5018 in the rack, you will need to open the unit to make sure the motherboard is
properly installed and all the connections have been made.
Accessing the Inside of the System (Figure 2-5)

1. First, grasp the two handles on either side and pull the unit straight out until it locks (you will hear a
"click").

2. Remove the five screws that hold the chassis cover in place.There are two screws on each side of the
chassis, and one screw on the back.

3. Once the screws have been removed, lift the cover upward to remove it from the chassis.

Checking the Components

4. Your RMC5018 server system may have come with system memory already installed. Make sure all
DIMMs are fully seated in their slots. For details on adding system memory, refer to Chapter 5.

5. If desired, you can install an add-on card to the system. See Chapter 5 for details on installing a PCI
add-on card.

6. Make sure all power and data cables are properly connected and not blocking the airflow. See Chapter
5 for details on cable connections.