RMC 5018

1U Rackmount System

© Copyright 2011 Acnodes, Inc.

All rights reserved. Product description and product specifications
are subject to change without notice. For latest product information,
please visit Acnodes’ web site at www.acnodes.com.

14628 Central Blvd,

Chino, CA91710

tel:909.597.7588, fax:909.597.1939







PCI IDE Bus Master

When enabled, the BIOS uses PCI bus mastering for reading/writing to IDE drives. The options are
Disabled and Enabled.

ROM Scan Ordering

This item determines what kind of option ROM activates over another. The options are Onboard First
and Add-on First.

PCI Slot 1

Use this feature to enable or disable PCI slot Option ROMs. The options are Dis- abled and Enabled.

Load Onboard LAN 1 Option ROM/ Load Onboard LAN 2 Option ROM

Select Enabled to load the onboard LAN Option ROM for the LAN port as specified. The options are
Enabled and Disabled.

Initiate Graphics Adapter

Use this feature to select the graphics controller to be used as the primary boot device. The options
are Other, Onboard VGA and Slot 6. Select Slot 6 if a graphics controller is installed in the CPU-
controlled Slot 6 slot.

XSuper IO Configuration

Serial Port1 Address/ Serial Port2 Address

This option specifies the base I/O port address and the Interrupt Request address of Serial Port 1
and Serial Port 2. Select Disabled to prevent the serial port from accessing any system resources.
When this option is set to Disabled, the serial port physically becomes unavailable. Select 3F8/IRQ4
to allow the serial port to use 3F8 as its I/O port address and IRQ 4 for the interrupt address. The
options for Serial Port1 are Disabled, 3F8/IRQ4, 3E8/IRQ4, 2E8/IRQ3. The options for Serial Port2
are Disabled, 2F8/IRQ3, 3E8/IRQ4, and 2E8/IRQ3.

XRemote Access Configuration

Remote Access

This allows the user to enable the Remote Access feature. The options are Dis- abled and Enabled.

If Remote Access is set to Enabled, the following items will display:

Serial Port Number

This feature allows the user decide which serial port to be used for Console

Redirection. The options are COM 1, COM 2 and COM 3.