Soft dB Tenor 24bits Data User Guide User Manual

Page 39

Advertising
background image

Tenor Data Logger

Soft dB inc.

Figure 29: Interface of the FRF module

At any time, the computation parameters can be changed and the recompute button can
be used to update the results.

The FRF interface has two graphs: 1) The FRF graph to present the amplitude (or the
phase) versus the frequency, and 2) the coherence graph. Three types of FRF can be
computed:

H1 using this equation:

H1=y/x=Sxy/Sxx

H2 using this equation:

H2=y/x=Syy/Sxy

H3 using this equation:

H3=y/x=(H1+H2)/2

Where x is the reference channel and y the second channel. In theory, all Hx must give the
same result. However, when the FRF contains resonance and/or anti-resonance, the result
can vary from one equation to another. In effect, noise on the X or Y channel on the anti-
resonance or resonance can distort the results. The H1 equation is better when the noise
is on the Y channel while the H2 equation gives better results when the noise is on the X
channel.

User Manual

p. 39

Advertising