VEGASEL

Product description

Level transistors

Number of transistors
- VEGASEL 543

1

- VEGASEL 544

2

- VEGASEL 545

3

- VEGASEL 546

4

- VEGASEL 547

2

Turn-on voltage U

B

max. 36 V DC

Switching current I

B

max. 60 mA DC (external limitation,
see 3 Electrical connection)

Voltage loss U

CE

1,5 V at I

B

= 60 mA

Function

Mode

Overfill protection (A)
Protection against dry running of pumps (B)

Switch point accuracy

1 %

Operating elements

Front plate

acc. to the version 2 or 4 coded keys
0 … 99 %

Circuit board

DIL-switch for adjustment

- mode A/B (for each relay)
- hysteresis 1 % or 3 % (for each relay)
- change-over 0/2 … 10 V, 0/4 … 20 mA
- change-over U-/I-input

Indicating elements

LED in front plate

green on: operating voltage on
yellow (per relay): switch point control

Ambient conditions

Permissible operating temperature

-20

°

C … +70

°

C

Storage and transport temperature

-25

°

C … +80

°

C

Electrical connection

Multiway connector carrier

acc. to DIN 41 612, series F, 48-poled, b, z
(partly equipped)

Carrier BGT 596

connection to respective module

Housing type 505

connection to screw terminals (max. 2,5 mm

2

)

Electrical protective measures

Protection

- not mounted

IP 00

- mounted into

carrier BGT 596
front side fully equipped IP 30
upper and lower side IP 00 (with BGT 596 Ex.M IP 20)
wiring side IP 00

- mounted into

housing type 505 IP 30

Protection class

II

Overvoltage category

II

Advertising