VEGA VEGAFLEX 52V User Manual

Page 15

Advertising
background image

VEGAFLEX 51V and 52V

15

Mounting / Installation instructions

Fig. 2.3 Humidity

Cable entries

When mounting outside, on cooled vessels or
in humid areas where cleaning is made e.g.
with steam or high pressure, the seal of the
cable entry is very important.

Use cable with a round cross-section area of
conductor and tighten the cable entry. The
cable entry is suitable for cable diameters of
5␣ mm to 9␣ mm.

Humidity from outside

To avoid humidity ingress, the connection line
to the housing should be looped directly
behind the cable entry to the bottom so that
rain and condensation water can drain off.
This is mainly valid for mounting outside, in
areas where humidity is expected (e.g. by
cleaning processes) or on cooled or heated
vessels (see fig. 2.3).

Advertising