5 technical data – VEGA VEGAFLEX 52V User Manual

Page 9

Advertising
background image

VEGAFLEX 51V and 52V

9

Product description / Technical data

1.5 Technical data

Power supply

Supply voltage

from signal conditioning instrument VEGAMET

or from the processing system VEGALOG 571
(max. 36 v DC)
fuse 0,5 A (slow-blow)

Current consumption

max. 22,5 mA

Power consumption

max. 80 mW, 0,45 VA

Measuring range

VEGAFLEX 51

0,3 … 10 m

VEGAFLEX 52

0,3 ... 20 m

Output signal

Digital measuring signal (VBUS)

Adjustment

- signal conditioning instruments VEGAMET 514V, 515V, 614V
- PC and adjustment software VEGA Visual Operating
- adjustment module MINICOM

Accuracy

(under reference conditions acc. to IEC 770 - relating to the max. meas. range)

Linearity error

< 0,1 %

Temperature drift

0,015 %/10 K

Resolution

1 mm

Characteristics

Min. span between full and empty adjustment

- digital output signal

10 mm

Ambient conditions

Vessel pressure

-1 … 16 bar

Ambient temperature on the housing

-40

°

C … +60

°

C

Process temperature

-40

°

C … +120

°

C

Storage and transport temperature

-40

°

C … +80

°

C

Protection

IP 66/IP 67 (meets both protections)

Protection class

- two-wire sensor

II

Overvoltage category

III

Max. tensile load

cable

4 mm 5 KN

cable

8 mm 20 KN

Ex-technical data

Dust-Ex

Zone 10

The permissible operating data of the VEGAFLEX-sensors for dust-Ex-areas are stated in
the certificate.

Advertising