4 type code – VEGA VEGAFLEX 52V User Manual
Page 8
8
VEGAFLEX 51V and 52V
Product description / Type code
1.4 Type code
The second figure of the type designation,
e.g. VEGAFLEX 5[1]… distinguishes the
instruments according to the stability of the
cable.
The figure e.g. VEGAFLEX 51[V] character-
izes the output signal:
K stands for an analogue 4␣ …␣ 20␣ mA output
signal (compact instrument)
V stands for a digital output signal (VBUS).
VEGAFLEX XX X EXS.X X
B - 20…72 V DC, 20...250 V AC / 4...20 mA-output, HART
®
D - Two-wire loop-powered / 4...20 mA-output, HART
®
E - Supply via signal conditioning instrument / V-BUS-output
Dust-Ex approved
V - Digital output signal (two-wire technology)
K - Analogue 0 … 20 mA output signal (two-wire or
four-wire technology)
Type 51:
Instrument series with 4 mm-cable
Type 52:
Instrument series with 8 mm-cable
Meas. principle (FLEX for guided microwave)