Page 20
20
VEGAFLEX 51V and 52V
Electrical connection / Connection of the sensor
3.2 Connection of the sensor
•
Loosen the closing screw on the upper
side of the sensor.
•
Open the sensor cover.
•
Remove the compression nut of the Pg
and shift the nut a little bit over the con-
nection cable.
•
Remove the rubber seal out of the Pg and
shift the seal over the connection cable.
•
Remove the cover of the connection cable
over a length of approx. 10 cm.
•
Loop the cable through the Pg into the
sensor.
Two-wire sensor
•
Connect the cable.
Push the white buckets of the spring
terminals with a small screwdriver and
insert the copper core of the connection
line into the terminal opening.
Check the position of the cables in the
terminal by slightly pulling.
•
Fasten the compression nut on the Pg.
VBUS
To the indicating instrument in the
sensor cover or to the external indicat-
ing instrument VEGADIS 50
M20 x 1,5
(diameter of the
connection cable
5…9␣ mm)