10 Tighten the compression nut of the cable entry, the seal

ring must completely encircle the cable

11 Connect the lead cable for power supply in the same way

acc. to the wiring plan, in addition connect the ground

conductor to the inner ground terminal.

12 Screw the housing cover back on
The electrical connection is hence finished.

Fig. 16: Connection steps 5 and 6

5.3 Wiring plan, double chamber housing

1

2

3

4

5

Fig. 17: Double chamber housing

1

Housing cover, connection compartment

2

Blind stopper or plug M12x1 for VEGADIS 61 (option)

3

Housing cover, electronics compartment

4

Filter element for pressure compensation or blind stopper with version IP 66/

IP 68, 1 bar

1)

5

Cable entry or plug

1)

Version IP 66/IP 68, 1 bar not with four-wire instruments

Housing overview

26

VEGASON 66 - Profibus PA

Connecting to voltage supply