VEGA VEGASON 66 Profibus PA User Manual

Page 56

Advertising
background image

Status

code

Description according to Profi-

bus standard

Possible cause

0x44

uncertain - last unstable value

Failsafe replacement value (Failsafe-Mode = "Last value" and already

valid measured value since switching on)

0x48

uncertain substiute set

l

Switch on simulation

l

Failsafe replacement value (Failsafe-Mode = "Fsafe value")

0x4c

uncertain - initial value

Failsafe replacement value (Failsafe-Mode = "Last valid value" and no

valid measured value since switching on)

0x51

uncertain - sensor; conversion not

accurate - low limited

Sensor value < lower limit

0x52

uncertain - sensor; conversion not

accurate - high limited

Sensor value > upper limit

0x80

good (non-cascade) - OK

OK

0x84

good (non-cascade) - active block

alarm

Static revision (FB, TB) changed (10 sec. long active after parameters

of the static category were written)

0x89

good (non-cascade) - active advi-

sory alarm - low limited

Lo-Alarm

0x8a

good (non-cascade) - active advi-

sory alarm - high limited

Hi-Alarm

0x8d

good (non-cascade) - active crit-

ical alarm - low limited

Lo-Lo-Alarm

0x8e

good (non-cascade) - active crit-

ical alarm - high limited

Hi-Hi-Alarm