1

2

L

Fig. 22: Data of the input variable
1 Min. level (red marking line)

2 Max. level

L Measuring range

Measuring range (L)

500 … 3000 mm (19.69 … 118.1 in)

Analogue input

Ʋ Input type

4 … 20 mA, passive

Ʋ Internal load

250 Ω

Switching input

Ʋ Type of input - Open Collector

10 mA

Ʋ Type of input - Relay contact

100 mA