VEGA VEGAWELL 72 4 … 20 mA_HART PT 100 User Manual
Page 15
Advertising
5
S
crew the screwed connection into the socket, fasten with
SW
30
and then fasten seal screw with SW 19
H
ow to correct the height:
1
L
oosen seal screw with SW 19
2
S
lide seal cone and cone sleeve to the requested position
on the cable
3
F
asten the seal screw
R
emoval is carried out in reverse order.
4
.4 Mounting steps with threaded connection or
housing
2
3
1
Fig. 5: Plastic housing
1
Housing
2
Seal
3
Thread
M
ount VEGAWELL 72 as follows:
1
W
eld the welded socket G1½ A or 1½ NPT to the vessel
top
2
S
hift transmitter through the mounting boss
Mount into the vessel
VEGAWELL
72 • 4 … 20
mA/HART PT
15
4 M
ounting
34360
-
EN
-080806
Advertising