Nominal range

Overload, max. pressure Overload, min. pressure

0 … 900

psig

2900

psig

-15

psig

A

bsolute pressure

0 … 15

psi

500

psi

0

psi

0 … 35

psi

700

psi

0

psi

0 … 70

psi

900

psi

0

psi

0 … 150

psi

1300

psi

0

psi

0 … 350

psi

1900

psi

0

psi

Output variable

O

utput signal

4 … 20

mA/HART

S

ignal resolution

2 µA

F

ailure signal

<

3.6

mA; 20.5 mA; 22 mA; unchanged

(

adjustable via PACTware)

M

ax. output current

22

mA

R

un-up time approx.

15

s

S

tep response time

200

ms (ti: 0 s, 0 … 63 %)

F

ulfilled NAMUR recommendations

NE

43

Additional output parameter - temperature
integrated resistance thermometer

P

t 100 according to DIN EN 60751

R

ange

-50 … +100 °C (-58 … +212 °F)

R

esolution

1 °K

Reference conditions and actuating variables (similar to DIN EN 60770-1)

R

eference conditions according to DIN EN 61298-1

-

T

emperature

+

15 … +25 °C (+59 … +77 °F)

-

R

elative humidity

45 … 75 %

-

A

ir pressure

860 … 1060

mbar/86 … 106 kPa

(12.5 … 15.4

psig)

D

etermination of characteristics

L

imit point adjustment according to

IEC

61298-2

C

haracteristics curve

linear

R

eference installation position

upright, diaphragm points downward

I

nfluence of the installation position

<

0.2

mbar/20 Pa (0.003 psig)

34

VEGAWELL

72 • 4 … 20

mA/HART PT

9 S

upplement

34360