.1 Technical data

General data

M

easured value

L

evel

M

easuring principle

C

eramic-capacitive, dry measuring cell

C

ommunication interface

HART

signal on 4 … 20 mA cable

Materials and weights

M

aterials, wetted parts

-

T

ransmitter

316L, 316L

with PE coating, 1.4462 (Duplex),

1.4462

with PE coating, PVDF, Titanium

-

P

rotective cap

PA, PE

-

D

iaphragm

sapphire ceramic

®

(99.9 %

oxide ceramic)

-

J

oining material diaphragm/Basic

element measuring cell

G

lass solder

-

M

easuring cell seal

FKM (VP2/A) - FDA

and KTW approved,

FFKM (K

alrez 6375), EPDM (A+P 75.5/

KW

75F)

-

S

uspension cable

PE (FDA

and KTW-approved), FEP, PUR

-

C

able gland on the transmitter

316L

-

C

able seal with PE, PUR cable

FKM

-

C

able seal with FEP cable

FEP

-

P

rocess fitting

316L

-

S

training clamp

1.4301

-

U

nassembled threaded fitting

316L, PVDF

-

T

hreaded connection on the hous-

ing

316L

M

aterials, non-wetted parts

-

H

ousing

plastic PBT (Polyester), 316L

-

type label support on cable

PE

hard

-

transport protection net

PE

W

eight approx.

-

B

asic weight

0.8

kg (1.764 lbs)

-

S

uspension cable

0.1

kg/m (0.07 lbs/ft)

-

S

training clamp

0.2

kg (0.441 lbs)

-

T

hreaded fitting

0.4

kg (0.882 lbs)

32

VEGAWELL

72 • 4 … 20

mA/HART PT

9 S

upplement

34360

-EN

-080806

Advertising