VEGA VEGAWELL 72 4 … 20 mA_HART PT 100 User Manual

Page 36

Advertising
background image

Total deviation (similar to DIN 16086)

T

he total deviation F

t

,

also called practical deviation, is the sum of the basic accuracy F

p

and long-term stability:

F

t

= F

p

+ F

s

F

perf

= √((F

T

)

2

+ (F

K

l

)

2

)

W

ith

-

F

t

: F

total

,

total deviation

-

F

p

: F

perf

,

basic accuracy

-

F

s

: F

stab

,

long-term drift

-

F

T

: T

emperature coefficient (influ-

ence of medium or ambient tem-
perature)

-

F

K

l

: D

eviation

Ambient conditions

A

mbient temperature

-

C

onnection cable PE

-40 … +60 °C (-40 … +140 °F)

-

C

onnection cable PUR, FEP

-40 … +80 °C (-40 … +176 °F)

S

torage and transport temperature

-40 … +80 °C (-40 … +176 °F)

Process conditions

M

ax. process pressure, transmitter

8)

-

M

easuring range 0.1 bar (1.45 psig)

15

bar (218 psig)

-

M

easuring range 0.2 bar (2.9 psig)

20

bar (290 psig)

-

M

easuring range ≤ 0.4 bar (5.8 psig)

25

bar (363 psig)

P

ressure stage, process fitting

-

U

nassembled threaded fitting

316L: PN 3, PVDF:

unpressurized

-

T

hread on the housing

PN

3

P

roduct temperature, depending on the version

Suspension cable

Measuring cell seal

Product temperature

PE

FKM

-20 … +60 °C (-4 … +140 °F)

PUR

FKM

-20 … +80 °C (-4 … +176 °F)

PUR

FFKM

-20 … +80 °C (-4 … +176 °F)

FEP

FFKM

-10 … +80 °C (+14 … +176 °F)

8)

L

imited by the overpressure resistance of the measuring cell.

36

VEGAWELL

72 • 4 … 20

mA/HART PT

9 S

upplement

34360

-EN

-080806