Insert the cable into the sensor through the cable entry

Fig. 7: Connection steps 5 and 6

6

Insert the wire ends into the terminals according to the wiring plan

Note:
Solid cores as well as flexible cores with cable end sleeves are
inserted directly into the terminal openings. In case of flexible cores
without end sleeves, press the terminal with a small screwdriver; the
terminal opening is freed. When the screwdriver is released, the
terminal closes again.

7

Check the hold of the wires in the terminals by lightly pulling on
them

8

Connect the screen to the internal ground terminal, connect the
outer ground terminal to potential equalisation

9

Attach the indicating and adjustment module again and turn it
slightly to the right

10 Tighten the compression nut of the cable glands. The seal ring

must completely encircle the cable

11 Screw the housing cover back on

The electrical connection is finished.