Status Commands

General Indications +WIND

©Restricted

Page:

118 / 184

This document is the sole and exclusive property of Wavecom. Not to be distributed or divulged without
prior written agreement.

WM_DEV_OAT_UGD_049 - 001

VOLUME 1

August 23, 2007

<Universal time

and local time

zone>:

indicates date, time and time zone expressed in quarters of an

hour, in format Year/Month/Day,Hour:Min:Seconds±TimeZone

string ("yy/MM/dd,hh:mm:ss±zz")

<LSA Identity>:

localized Service Area identity of the current cell in hexa format

(3 bytes)

hexa string

<Daylight Saving

Time>:

when the local time zone is compensated for DST (Day Saving

time, or summertime), the serving PLMN shall provide a DST

parameter to indicate it. The adjustment for DST can be +1h or

+2h.

range: 0-2

7.1.4

Parameter Storage

The <IndLevel> parameter is stored in EEPROM without using AT&W command. The

default value can be restored using AT&F.

7.1.5

Examples

Command

Responses

AT+WIND?

+WIND: 0

OK

AT+WIND=255

OK

Note: The SIM has been
removed

+WIND: 0

Note: The SIM presence pin has been detected as "SIM removed"

Note: The SIM has been inserted

+WIND: 1

Note: The SIM presence pin has been detected as "SIM inserted"

Note: The network service is available

for an emergency call

+WIND: 7

Note: The initialization has been

completed

+WIND: 4

Note: The Wireless CPU

®

received a

NITZ information message

+WIND: 15,1,"Cingular

Extend",2,"Cingular",3,"+08",4,"03/14/27,1
6:59:48+08",5,"123456",6,"2"