Open at, Commands, At+wopen=5 – Rainbow Electronics FARGO MAESTRO 100 (with TCP_IP) User Manual

Page 51: Cme error: 3, At+wopen=1, Ok +wind: 3, Ok at+wopen? +wopen:5 ok

Advertising
background image


Open AT

®

Commands

Wavecom Open AT

®

Control Command +WOPEN

©Restricted

Page:

45 / 184

This document is the sole and exclusive property of Wavecom. Not to be distributed or divulged without
prior written agreement.

WM_DEV_OAT_UGD_049 - 001

VOLUME 1

August 23, 2007

Command

Responses

AT+WOPEN=6,768

+WOPEN: 6,768,832

OK

Note: No product reset (same size used)

AT+WOPEN=6,900

+WOPEN: 6,960,640

OK

+WIND: 3

Note: Size updated according to the nearest flash sector

sub-division. Product reset in order to set the new A&D

storage place size.

AT+WOPEN=6

+WOPEN: 6,960,640

OK

Note: 960 Kbytes are reserved for the A&D storage place,

and 640 for the Open AT

®

application

AT+WOPEN=5

Note: Suspend Open AT

®

tasks

+CME ERROR: 3

Note: The Open AT

®

application is not running

AT+WOPEN=1

Note: Start the embedded application

OK

+WIND: 3

Note: Product reset in order to start the embedded

application

AT+WOPEN=5

Note: Suspend Open AT

®

tasks

OK

AT+WOPEN?

+WOPEN:5

OK

5.2.6

Notes

For mode = 1: if the main version numbers returned by the AT+WOPEN=2 command

do not match, the command will reply "+CME ERROR: 541"

<Mode> = 3 and <Mode> = 4 are only available if the Open AT

®

embedded

application is stopped (AT+WOPEN=0).

Open AT

®

embedded applications can be resumed with +WOPENRES command or

the "INTERRUPT" feature (see +WCFM command).

The command returns an error when trying to use a key not available for Open AT

®

Safe Boot.

Advertising