14

OUTDIV

Output frequency range of PLL.

JCIDBG

This field controls the mode of the JCI. The Oak subsystem has its own JTAG port. This port is used to communicate
serially with the Oak OCEM module.

SIAP-E ID Register

Register Name: SIAP_ID
Access: Read-only
Reset Value: 0x00000220 in small bond-out mode

0x0001220 in large bond-out mode

IDENT: Identifier

This field indicates the device identifier 0x0220.

PKG: Package

This bit reflects the state of the data bus width signal DBW and indicates the SIAP package size.

OUTDIV

PLL Output Frequency Range

0

0

40 MHz to 250 MHz

0

1

20 MHz to 40 MHz

1

0

10 MHz to 20 MHz

1

1

5 MHz to 10 MHz

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

PKG

15

14

13

12

11

10

9

8

IDENT

7

6

5

4

3

2

1

0