GE Zenith Controls

13

MX150/MX250 Series Modbus Network Card (71R-2200)

Appendix B - Read/Write Register List

Holding Reg. Bit Coil Description

Range

Notes

40033

P Timer Setting

0 - 1000 1/100 of a second

40034

W Timer Setting

0 - 300 seconds

40035

T3/W3 Timer Setting (Mirror of 40038) 0 - 60 seconds

40036

DW Timer Setting

0 - 600 seconds

40037

T Timer Setting

0 - 3600 seconds

40038

T3/W3 Timer Setting (Mirror of 40035) 0 - 60 seconds

40039

DT Timer Setting

0 - 600 seconds

40040

U Timer Setting

0 - 3600 seconds

40041

S1 Undervolt Restore

85 - 100 percent

Must be at least 2 > S1 UV Fail

40042

S1 Undervolt Fail

75 - 98 percent

Must be at least 2 < S1 UV Restore

40043

S2 Undervolt Restore

85 - 100 percent

Must be at least 2 > S2 UV Fail

40044

S2 Undervolt Fail

75 - 98 percent

Must be at least 2 < S2 UV Restore

40045

S1 Underfreq Restore

90 - 100 percent

Must be at least 2 > S1 UF Fail

40046

S2 Underfreq Restore

90 - 100 percent

Must be at least 2 > S2 UF Fail

40047

Net Control 0

0

65 Reset Time S2 Available

1 = Reset

1

66 Alarm Silence

1 = Silence Alarm

2 67 Unused

3

68 YE Control

1 = Bypass to S2

4

69 YN Control

1 = Bypass to S1

5

70 No Load Test Control

1 = Start Test

6

71 Load Test Control

1 = Start Test

7

72 Fast Load Test Control

1 = Start Test

40048

Net Control 1

0

73

Unused

1 74 S5 Control

1 = On, 0 = Off

2 75 S12 Control

1 = On, 0 = Off

3

76 LS Control

1 = On, 0 = Off

4 77 Q7 Control

1 = On, 0 = Off

5

78 Q3 Control

1 = On, 0 = Off

6

79 Aux 2 Control

1 = On, 0 = Off

7

80 TMS Control

1 = On, 0 = Off

40078

UMD Timer Setting

0 - 300 seconds

40079

Phase Imbalance Timer Setting

10 - 30 seconds

40080

Phase Imbalance Fail Setting

5 - 20 percent

40081

Phase Imbalance Restore Setting

3 - 18 percent

40084

S1 Overvolt Fail

105 - 110 percent

Must be at least 2 > S1 OV Restore

40085

S1 Overvolt Restore

103 - 108 percent

Must be at least 2 < S1 OV Fail

40086

S2 Overvolt Fail

105 - 110 percent

Must be at least 2 > S2 OV Restore

40087

S2 Overvolt Restore

103 - 108 percent

Must be at least 2 < S2 OV Fail

40088

S1 Underfreq Fail

88 - 98 percent

Must be at least 2 < S1 UF Restore

40089

S1 Overfreq Fail

103 - 105 percent

Must be at least 1 > S1 OF Restore

40090

S1 Overfreq Restore

102 - 104 percent

Must be at least 1 < S1 OF Fail

40091

S2 Underfreq Fail

88 - 98 percent

Must be at least 2 < S2 UF Restore

40092

S2 Overfreq Fail

103 - 105 percent

Must be at least 1 > S2 OF Restore

40093

S2 Overfreq Restore

102 - 104 percent

Must be at least 1 < S2 OF Fail

Advertising