Object_Name

Description

R/W

NV

Units

Range

Additional information

AI40

Pulse_Count_1

Pulse Count #1

R

NV

#

0 - 4294967040

Running count of contact closures on Pulse1 input since

last reset. Write 16498 (0x4072) to the Present_Value

property of Analog_Value object AV1 to reset both

Pulse Counters to 0.

AI41

Pulse_Count_2

Pulse Count #2

R

NV

#

0 - 4294967040

Pulse Count 2; Running count of contact closures on

Pulse2 input since last reset. Write 16498 (0x4072) to

the Present_Value property of Analog_Value object

AV1 to reset both Pulse Counters to 0.

AI42

KWH_A

Real Energy

Consumption

Phase A

R

NV

kWh

0 - 3.4+E38

AI43

KWH_B

Real Energy

Consumption

Phase B

R

NV

kWh

0 - 3.4+E38

AI44

KWH_C

Real Energy

Consumption

Phase C

R

NV

kWh

0 - 3.4+E38

AI45

Max_Power

Theoretical

Maximum System

Power

R

NV

kW

0 - 1.84467e19

Theoretical Maximum System Power – This is the

theoretical maximum power the meter expects to

see on a service. It is calculated by the meter from the

System Type (in object AV2), CT Size (in object AV3),

and System Voltage (in object AV6) - Power Factor is

assumed to be unity. The register is updated whenever

the user changes any of these parameters.

AI46

Reserved_AI46

Reserved

R

0

Returns QNAN or any value

AI47

Energy Resets

Count of Energy

Accumulator Resets

R

NV

0 - 32767

Running count of how many times the energy counter

has been reset

AI48

Reserved_AI48

Reserved

R

0

Returns QNAN or any value

AI49

Reserved_AI49

Reserved

R

0

Returns QNAN or any value

AI50

Power Up Count

Power Up Counter

R

NV

0 - 32767

Running count of product power-up cycles (Control

Power)

AI51

Ouput Config

Ouput Configuration R

NV

0 - 15

Returns “0”

AI52

Reserved_AI52

Alert Summary

Register

R

0 - 32767

This contains a decimal value that represents the status

of all Binary_Object alert values in one number that

can be read without having to access mulitple objects.

It is a decimal representation of a 15-bit hexidecimal

value produced by combining the 15 alert bits into one

number, where the bit value of Object BI1 is the least

significant bit and BI15 is the most significant bit.