Absolute maximum ratings, Electrical specifications, Car2912te series front-end – GE Industrial Solutions CAR2912TE series User Manual

Page 2: Preliminary data sheet

Advertising
background image

GE

Preliminary Data Sheet

CAR2912TE series front-end

Input: 90Vac to 264Vac; Output: 12Vdc @ 2900W; 3.3 or 5Vdc @ 4A Standby

October 21, 2013

©2013 General Electric Company. All rights reserved.

Page 2

Absolute Maximum Ratings

Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional

operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure

to absolute maximum ratings for extended periods can adversely affect the device reliability.

Parameter

Symbol

Min

Max

Unit

Input Voltage: Continuous

V

IN

0

264

V

AC

Operating Ambient Temperature

T

A

-10

70

1

°C

Storage Temperature

Tstg

-40

85

°C

I/O Isolation voltage to Frame (100% factory Hi-Pot tested)

2121

V

DC

Electrical Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, load, and temperature conditions.

INPUT

Parameter

Symbol

Min

Typ

Max

Unit

Operational Range

V

IN

85

115/230

264

V

AC

Frequency Range (ETSI 300-132-1 recommendation)

F

IN

47

50/60

63

Hz

Main Output Turn OFF

V

IN

70

80

V

AC

Main Outptut Turn ON

75

85

Hysteresis between turn OFF and turn ON

5

Maximum Input Current (V

O

= V

O, set

, I

O

=I

O, max

) V

IN

= 100V

AC

I

IN

16.3

15.9

A

AC

V

IN

= 208V

AC

Cold Start Inrush Current (Excluding x-caps, 25°C, <10ms,

per ETSI 300-132)

I

IN

40

A

PEAK

Efficiency (T

amb

=25°C, V

O

= 12V) V

IN

100% load

50% load

20% load

10% load

η

115V / 230V

92 / 93.5

93 / 96

92 / 94.0

88 / 91.5

%

Power Factor (V

IN

=115/230V

AC

), I

O

= 50% I

O, max

I

O

= I

O, max

PF

0.98

0.99

Holdup time (Vout≥ 10.8V

DC

, Tamb 25°C, I

O

=I

O, max

) V

in

= 230V

AC

V

IN

= 100V

AC

T

12

20

ms

Early warning prior to output falling below regulation

2

2

Ride through

T

10

Leakage Current (V

IN

= 250V

AC

, F

IN

= 60Hz)

I

IN

3

mA

RMS

Isolation Input/Output

3000

V

AC

Input/Frame

2121

V

DC

Output/Frame

100

V

DC

12V

dc

MAIN OUTPUT

Parameter

Symbol

Min

Typ

Max

Unit

Output Power 180 – 264 / 90-132 Vac

W

0

-

2900/1400

W

V

AC

≤ 90V

AC

0

-

1200

W

Set point

V

O

11.9

12.00

12.1

V

DC

Overall regulation (load, temperature)

-2

+2

%

1

Power derated above 50°C, see environmental section

2

Measured by the DC_OK signal going LO prior to the output decaying below 10.8Vdc