Alarm table, Outline drawing, Car2912te series front-end – GE Industrial Solutions CAR2912TE series User Manual
Page 23: Preliminary data sheet
GE
Preliminary Data Sheet
CAR2912TE series front-end
Input: 90Vac to 264Vac; Output: 12Vdc @ 2900W; 3.3 or 5Vdc @ 4A Standby
October 21, 2013
©2013 General Electric Company. All rights reserved.
Page 23
Alarm Table
Test Condition
LED Indicator
Monitoring Signals
LED1
INPUT OK
Tri-Color LED2
Temp OK/DC OK / Fault
FAULT
DC OK
INPUT OK
TEMP OK
1
Normal Operation
Green
Green
High
High
High
High
2
Out of range INPUT
Blinking
OFF
High
Low
Pulsing
High
3
No Input
OFF
OFF
High
Low
Low
High
4
OVP
Green
Red
Low
Low
High
High
5
Over Current
Green
Blinking
High
Pulsing
High
High
6
Over Temp Warning
Green
Blinking Red
High
High
High
Pulsing
7
Over Temp Fault
Green
Red
Low
Low
High
Low
8
Remote ON
Green
Green
High
High
High
High
9
Remote OFF
Green
OFF
High
Low
High
High
Notes: Test condition #2 and #3 had 2 modules plug in. One module is running and the other one is with no/low AC.
Outline Drawing
16.80 ± .020
[426.72 ±.508]
17.242 ±.020
[437.95] ±.508