Failure reporting form for power circuit breakers – GE Industrial Solutions Power-Vac ML-20 Mechanism User Manual

Page 37

Advertising
background image

USER REPORT NO.


FAILURE REPORTING FORM FOR POWER CIRCUIT BREAKERS


Check all appropriate blocks and provide information indicated. For major trouble provide additional information requested on back of
page supplemented with additional pages if necessary.
User

Ident

EQUIPMENT:

Station____________________________

of

Breaker___________________

Equipment Nameplate Mfgr._______________________________Type_______________

Serial

#_____________________

Information kV_______Inter Amps/MVA___________________Continuous Amps__________ BIL______________

Trouble

Breaker Background: Shipped________, Installed________, Maintained_________, Modernized_______, Date _____________
(Mo/Yr)

(Mo/Yr)

(Mo/Yr)

(Mo/Day/Yr)

Operational Counter Reading _________________________________________________________________________________
Location:

! Indoor

! Outdoor

Enclosure:

! Non-metal Clad, ! Metalclad, ! GIS

Interrupter:

! Air Blast, ! Air Magnetic, ! Oil, ! SF

6

,

! Vacuum, Other____________________________________

ENVIRONMENT:

General:

! Industrial, ! Urban, ! Suburban, ! Rural, ! Sea Coast, ! Above 3300', ! High Contamination,

Other________________________________________________________________________________________
Weather Conditions:

! Dry, ! Rain, ! Lightning in Area, ! Snow, ! Fog, ! Freezing Rain, ! Frost, ! Condensation,

Temp. Trend

! Rising, ! Falling, ! Steady, ! Extreme Cold, Temperature_____

°

F,

Wind

! Calm, ! Light, ! Strong-Steady, ! Strong-Gusty

External Mechanical Stresses Involved:

! Normal, ! Earthquake, ! Wind, ! Abnormal Terminal Loading,

Other___________________________________________________________________________________________________

Nominal System voltage__________________________

TROUBLE:
When Discovered:

! Installation, ! In Service, ! Maintenance, ! Test, Other _____________________________________

Breaker Mode at Time of Trouble:

! De-energized, ! Closed, ! Open, ! Tripping, ! Closing, ! Reclosing,

! Fault Interruption, ! Load Switching, ! Line Switching

Breaker Response at Time of Trouble:

! Not Called Upon to Operate, ! Performed at Intended, ! Unsatisfactory Operation,

! Failed to Operate

Subsystem in Trouble:

! External Insulation to Ground, ! Internal Insulation to Ground, ! Insulating Medium,

! Isolating Contact, ! Bushing, ! Interrupter, ! Seals-Gaskets, ! Air System, ! SF

6

System,

! C.T.,

! Resistor Sw or Aux. Int., ! Voltage Grading Device, ! Line Terminals, ! Compressor, ! Heater, ! Electrical Controls,

! Wiring, ! Operating Mechanism, ! Mechanical Linkage, ! Other _______________________________________________

________________________________________________________________________________________________________

State Specifically What Failed (With Instr. Book Ref.):____________________________________________________________

________________________________________________________________________________________________________

Has it occurred before on this type of breaker?

! No, ! Yes, How many times______________________________________

State How Problem was Corrected

:

___________________________________________________________________________

________________________________________________________________________________________________________

POSSIBLE CAUSE:

! Design/Manufacture, ! Shipping, ! Storage, ! Installation, ! Instructions, ! Maintenance,

! Wear/Aging, ! Animal/Birds, ! Other, ! Not Obvious

Comments and Suggestions: _______________________________________________________________________________

________________________________________________________________________________________________________

________________________________________________________________________________________________________
EFFECT:
Breaker Down Time:

! No Interruption, ! 30 Min. or Less, ! 1 Hr, ! 2 Hr, ! 6 Hr, ! 12 Hr, ! 24 Hr, Other ______________

Repair Time:

! Less than 30 Min., ! 1 Hr, ! 2 Hr, ! 6 Hr, ! 1 Day, ! 2 Days, ! 3 Days, ! 1 Week, Other ______________

Breaker Outage Status:

! Immediate Forced Outage, ! Outage Within 20 Min., ! Required Subsequent Outage,

! Repair Deferred Until Regular Maintenance, ! No Outage for Repair

User Person
Completing Report ______________________________________________________Date__________________________________

User Approval Name_____________________________________________________Date _________________________________

User Contact Name____________________________________________Telephone Number________________________________

User Company_______________________________________________