GE Industrial Solutions AF-300 P11 User Manual

Page 140

Advertising
background image

12-5

Data subject to change without notice 7/07. © 2007 GE Drives

Code

Code

0

No alarm

—-

22

Overheat, DB resistor

dbH

1

Overcurrent, during acceleration (INV output )

OC1

23

Overload, motor 1

OL1

2

Overcurrent, during deceleration (INV output )

OC2

24

Overload, motor 2

OL2

3

Overcurrent, during steady state operation
(INV output )

OC3

25

Overload, drive

OLU

5

Ground fault

EF

27

Overspeed

OS

6

Overvoltage, during acceleration

OU1

28

PG wire break

Pg

7

Over voltage, during deceleration

OU2

31

Memory error

Er1

8

Overvoltage, during steady state operation

OU3

32

Keypad error

Er2

10

DC undervoltage

LU

33

CPU error

Er3

11

Power supply open phase

Lin

34

Option comm error

Er4

14

Blown DC fuse

FUS

35

Option error

Er5

16

Output wiring error

Er7

36

PL error

Er6

17

Overheat, heat sink, inverter

OH1

37

Output wiring error

Er7

18

Overheat, outside thermal

OH2

38

RS485 comm error

Er8

19

Overheat, unit inside temp

OH3

Description

Description

Data format [11]

Capacity code

Code

Capacity (HP)

Code

Capacity (HP)

Code

Capacity (HP)

7

0.07 (spare)

2000

20

17500

175

15

0.15 (spare)

2500

25

20000

200

25

0.25

3000

30

25000

250

50

0.5

4000

40

30000

300

100

1

5000

50

35000

350

200

2

6000

60

40000

400

300

3

7500

75

45000

450

500

5

10000

100

50000

500

750

7.5

12500

125

60600

600

1000

10

15000

150

60700

700

1500

15

60800

800

Data format [12]

Index data (ACC/DEC time, display coefficient)

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

0: Positive (+),

Polarity 0

0

0 Index portion

Data portion

1: Negative ( - )

0: 0.01 X
1: 0.1

X

2: 1

X

3: 10

X

001–999

(0.00–9.99)

00–999

(10.0–99.9)

100–999

(100–999)

100–999

(1000–9990)

Example: If F07 (acceleration time 1) = 20.0 s

10.0 < 20< 99.9 ➞ index =1
20.0 = 0.1 X 200 ➞ 0400

H

+ 00C8

H

= 04C8

H