Bell & Gossett IM193 R03 Rev 2 Battery Backup Sump Pump User Manual

Page 4

Advertising
background image

4

BATTERY REQUIREMENTS

Hazardous electrical current.

Can cause severe burns and start a fire if battery termi-

nals are short circuited. Install battery in box. To prevent

accidental shorting across battery terminals, strap cover

securely on battery box. Do not leave battery uncovered.

Do not allow children to play around sump pump

installation.
Your backup sump pump depends on the battery used

with it for power. The better the battery, the better the

performance of the pump.
We recommend the use of a 105 Amp Deep Cycle

Marine Battery.
This battery will perform well for many hours and stands

up well to long periods of little or no use.

Use of a standard automobile or marine

battery with this charger is not recom-

mended. An automobile battery may

require charging after only 1-2 hours of

continuous use, and the repeated charg-

ing cycles may cause early plate failure

in the battery.
Use only a new, fully charged battery

that will fit in the battery box (maxi-

mum size 12

5

8

" long, 7" wide and 9

3

8

"

high (320.7 mm x 177.8 mm x 238 mm)

including terminals).

PUMP INSTALLATION AND OPERATION
NOTICE:
We recommend a trial fitting of all

components before gluing anything. This

will allow you to check pump mounting

height, float switch clearance, etc., while

adjustments can still be easily made.

1. Fill sump until primary pump turns on. Mark this

level as “Normal High Water”.

2. When installing the pump, mount the centerline of

the tee inlet at least 2 inches above the normal high

water level.

3. Check that the location of the tee is at least 2 inches

below the top of the sump.

4. Make sure the installation will not interfere with the

primary sump pump operation as follows:

(A) Back up pump must not interfere with primary

pump float switch swing.

(B) Normal high water level must not be high

enough to start the back-up pump.

(C) Install a check valve in the main sump pump

discharge pipe below the back-up pump tee.

Flow in this pipe must be away from the primary

pump. DO NOT INSTALL IT BACKWARDS!

This valve will prevent flow from the back-up

pump back to the sump during battery powered

operation.
5. Cut rigid discharge pipe from primary sump pump

to length, use PVC piping. Tee supplied is 1½" slip

fit; if necessary use 1¼" bushings supplied. Do not

glue the tee until all parts have been trial

fitted and aligned.

WARNING

CAUTION

FIGURE 1

Standard Installation

CL

pump

PUMP

PUMP

PRIMARY

DISCHARGE

PIPE

CHECK

VALVE

CHECK

VALVE

ELBOW

TEE

3

12

11

FIGURE 2

Assembly Details

TEE

SW

FLOAT

SW

BACK UP

PUMP

MAX.

MAX.

*PRIMARY

PUMP

SUMP

CHECK VALVE

Must be

installed

to prevent

recirculation

into sump.

“ON”

POSITION

(Primary pump

normal high

water level)

TOP OF SUMP

2" MIN.

2" MIN.

1.6 REF.

Advertising