5

E. Connect the black pump wire to the Negative

battery

terminal.

F. Connect the gray switch wire marked + to the

Positive battery terminal.

2. Plug in power cord to a 115-125 Volt AC outlet

delivering at least 2 amps. Do not use a switch

controlled outlet. Mark circuit in main power panel

“Backup sump pump power supply; do not turn off ”.

3. With charger properly connected and plugged in, the

panel on the front of the charger will appear as in

one of the following:

A. If battery is dead, charger will supply about

10 amps power (see Figure 3A).

B. If battery is near full charge, charger will deliver

about 5 amps power (see figure 3B).

C. If battery is fully charged, charging current will

be 0 amps and green LED lamp will be lighted

(see figure 3C).

4. The charger is equipped with a self-resetting circuit

breaker which protects it from temporary overloads.

In case of an overload, the circuit breaker will open.

It automatically resets after a short cool-down

period. In some conditions where the overload is

extended the breaker will cycle, repeating the open/

reset process indefinitely. When this happens,

normally the charger will emit a clicking sound as

the breaker opens and resets.

NOTICE: If the clicking sound continues for more

than 30 minutes or so, check for reversed

charger connections to the battery and for

shorted cells in the battery.

BATTERY MAINTENANCE
NOTICE:
To protect battery case from chipping and

gouging, do not let battery sit on concrete

floor (plywood, 2x4’s, etc.). Always install

battery in a dry location that is protected

from flooding.

1. Unplug battery charger.
2. On batteries with removable top caps, measure

specific gravity of electrolyte. Use a hydrometer

(available at auto parts stores). If the specific gravity

of any cell is less than 1.225 or if there is more than

.050 variation between cells, replace the battery.

3. Check electrolyte level and refill as needed.
4. Check battery terminals and clamps for tightness and

corrosion. Clean and tighten as needed.

5. Plug in battery charger.

6. Thread check valve tightly into the elbow provided

and plug the pump discharge into the other end of

the elbow. Secure with hose clamp. Slip the plain end

of the check valve into the side socket of the tee.

7. Install the float switch on the stainless steel bracket

provided and attach the bracket as shown.

Adjust bracket to support pump/switch assembly to

approximately level position.

8. Check for clearance to all working parts of the

primary and back-up pump systems.

9. Remove pump assembly from tee. Remove tee

from pump.

10. Using PVC cement, permanently install the tee on

the discharge pipe, according to the PVC cement

instructions.

Hazardous Fumes. Follow cement

manufacturer’s instructions. Use PVC

cement only in a well ventilated area

away from fire or flame.

11. Reinstall switch/bracket assembly.
12. Using PVC cement, permanently install the pump

assembly by cementing the check valve in the tee side

socket, with the pump base approximately level.

13. Adjust the switch/bracket assembly to support the

pump. Tighten the clamp.

14. Make sure battery is fully charged: then check

operation by disconnecting power to the primary

sump pump and filling sump until the battery

operated pump starts. Run pump through one

complete cycle.

15. Operation may be checked at any time by rotating

the float switch knob or ribbed wheel (4) pivots to

turn on the pump.

The liquid sound you hear in the float

portion of the switch is mercury, not

water, and should be disposed of prop-

erly. If you cannot arrange for proper

disposal, the product may be returned

for disposal to place of purchase.

ELECTRICAL CONNECTIONS

Hazardous Voltage. Can cause serious

or fatal electrical shock. Review safety

instructions before operating charger.

Do not modify cord or plug.
CHARGER/BATTERY INSTALLATION
NOTICE:
Alarm will sound when charger is first

connected to battery. Press ALARM TEST/

RESET button on charger. If alarm continues

to sound, disconnect one charger lead from

the battery and reconnect it. Press ALARM

TEST/RESET again; alarm will stop

sounding.
1. Connect charger as shown in Figure 3.

A. Connect Positive (+) lead from charger to

positive battery terminal.

B. Connect (–) lead from charger to negative

battery

terminal.

C. Connect the third (blue) lead from the charger to

the blue tap on the brown pump wire just before

the fuse holder.

D. Put the 15 Amp fuse into ½ of the fuse holder

and connect the second half of the fuse holder.

WARNING

CAUTION

WARNING

FIGURE 3 –

Battery Backup

Control Panel

A. Battery depleted –

charging current

10 Amps.

B. Battery nearly

charged – current

about 5 Amps.

C. Charge complete –

current 0 amps,

LED lights up.

3A.

3B.