Bell & Gossett IM193 R03 Rev 2 Battery Backup Sump Pump User Manual

Page 7

Advertising
background image

7

TROUBLESHOOTING
Pump won’t run:

1. Check all connections.
2. Check for low or defective battery.
3. Check that automatic switch is operating properly.
4. Blown fuse in switch circuit. Unplug pump and re

move the strainer. Check to see if impeller is free

to turn. If impeller is locked remove the obstruction.

Replace strainer and fuse.

Motor hums but pump won’t run:

1. Check for low or defective battery.
Pump runs but pumps very little or no water:

1. Make sure a check valve is installed and

functioning between primary pump discharge and

backup sump pump tee.

2. Check for obstruction in discharge pipe.
3. Discharge pipe length and/or height exceeds capacity

of pump. See Table 1 for pump capacity.

4. Check for low or defective battery.
5. Drill a

1

16

to

1

8

inch diameter vent hole between

pump discharge and check valve.

Pump cycles too frequently:

1. Main check valve located between discharge of

primary pump and the backup sump pump tee or

check valve not installed or working properly. Install

or repair as required.

NOTE:

“Deep Cycle Marine” batteries are different

than marine and automotive batteries!

Advertising