John Wood Takagi - 110-310-510 User Manual

Page 19

Advertising
background image

19

(A) 510 Computer board

Easy-Link system

“Online” LED

Left bank of

DIPswitches

7-Seg. LED

Right bank of

DIPswitches

Easy-Link connectors

are next to the

computer board.

To change the DIPswitch settings for the Easy-Link system,
locate the bank of DIPswitches to the right of the 7-seg LED.
Do not adjust the left bank of DIPswitches.

(B) Basic diagram of connections between the Easy-Link
System units.

Communication

cable

Connectors

Right bank of

Dipswitches

OFF

ON

1 2 3 4 5 6

PARENT

1

2

Connectors

Right bank of

Dipswitches

OFF

ON

1 2 3 4 5 6

PARENT

1

2

Connectors

Right bank of

Dipswitches

OFF

ON

1 2 3 4 5 6

PARENT

1

2

Connectors

Right bank of

Dipswitches

OFF

ON

1 2 3 4 5 6

PARENT

1

2

PARENT

unit

CHILD-1

unit

CHILD-2

unit

CHILD-3

unit

CAUTION

The dark squares indicate the direction the
DIPswitches should be set to.

Note:

A remote controller is not required for the Easy-Link
system.
If running the Easy-Link system without a remote control-
ler, please make sure the temperature settings on ALL
the units are set to the same settings. Otherwise, the
units will not operate properly.
If a remote controller is used, the temperature on all the
units in the system will automatically be set to the same
temperature that is set on the remote.

(C) Examples of incorrect settings and/or connections
CASE 1:

Unless you change DIPswitch No. 1 of the “PARENT”
unit to the “ON” position, the system will not work as an
Easy-Link system. The units will operate as individual
units.

Communication

cable

Connectors

Right bank of

Dipswitches

OFF

ON

1 2 3 4 5 6

PARENT

1

2

Connectors

Right bank of

Dipswitches

OFF

ON

1 2 3 4 5 6

PARENT

1

2

PARENT

unit

CHILD-1

unit

Wrong
setting

Prohibited

Wrong DIPswitch setting on the “PARENT”
unit

CASE 2:

If you connect the “1" (or "2") connector of the “PARENT”
unit to the “PARENT" (or "1") connector of the “CHILD-1”
unit, the system will not work as an Easy-link system.
The units will operate as individual units.

Communication

cable

Connectors

Right bank of

Dipswitches

OFF

ON

1 2 3 4 5 6

PARENT

1

2

Connectors

Right bank of

Dipswitches

OFF

ON

1 2 3 4 5 6

PARENT

1

2

PARENT

unit

CHILD-1

unit

Wrong

connection

Wrong

connection

OR

Communication

cable

Connectors

Right bank of

Dipswitches

OFF

ON

1 2 3 4 5 6

PARENT

1

2

Connectors

Right bank of

Dipswitches

OFF

ON

1 2 3 4 5 6

PARENT

1

2

PARENT

unit

CHILD-1

unit

Wrong

connection

Wrong

connection

Prohibited

Wrong connections between the “PARENT”
unit and the “CHILD-1” unit

Advertising