John Wood Takagi - 110-310-510 User Manual

Page 26

Advertising
background image

26

WARNING

DO NOT set to 85°C (185°F) if you use
your water heater in a recirculation
system. This will cause damage to the
heater and void the warranty. (This
temperature setting is only available
on the 510 models).
DO NOT adjust the left bank of
DIPswitches. (For the 510 models).
Turn off the power supply to the water
heater before changing the DIPswitch
settings.
Only change the switches with the dark
squares. The dark squares indicate
which direction the DIPswitch should be
set to.

Flow

The flow rate through the water heater is limited to a
maximum of 25 l/min (6.6 GPM (US)) for the 110, 30.3
l/min (8.0 GPM (US)) for the 310, and 37.8 l/min (10.0
GPM (US)) for the 510.
The temperature setting, along with the supply tempera-
ture of the water will determine the flow rate output of
the unit.
Please refer to the temperature vs. gallons per minute
charts on pg. 43 to determine the likely flow rates based
on your local ground water temperature and your desired
outlet water temperature.

Household Flow Rates

Appliance/Use

Flow Rate

l/min

GPM (US)

Lavatory Faucet

3.78

1.0

Bath Tub

15.2 - 37.8

4.0 – 10.0

Shower

7.5

2.0

Kitchen Sink

5.6

1.5

Dishwasher

5.6

1.5

Washing machine

15.2

4.0

Taken from UPC 2006

Based on the CAN/CSA P.7 test method for measuring
energy loss of gas-fired instantaneous water heaters, the
water heater is rated for litres per hour (l/hr) ((US) gallons
per hour (GPH)) or litres per minute (l/min) ((US) gallons
per minute (GPM)) for Natural Gas and Propane, when
raising the water temperature by 43C° (77F°) (from 14°C
to 57°C (58°F to 135°F)). See the following chart.

Model

Unit of

Measure

Natural Gas

Propane

110

l/hr

681

681

l/min

11.35

11.35

GPH (US)

180

180

GPM (US)

3

3

310

l/hr

931

931

l/min

15.5

15.5

GPH (US)

246

246

GPM (US)

4.1

4.1

510

l/hr

954

954

l/min

15.9

15.9

GPH (US)

252

252

GPM (US)

4.2

4.2

Refer to the table on the left for typical household plumb-
ing fixture flow rates to determine what the water heater
can do in a household application.

Freeze protection system

This unit comes equipped with heating blocks to protect
it against damages associated with freezing.
For this freeze protection system to operate there has
to be electrical power to the unit. Damage to the heat
exchanger caused by freezing temperatures due to
power loss is not covered under the warranty. In cases
where power losses can occur, consider the use of a
backup power supply.
The freeze protection system will activate when the sur-
rounding and/or outside temperatures drop below 2.5°C
(36.5°F).
For the 110, 310, & 510:

In any areas subject to freezing temperatures, freez-
ing issues can only occur if cold air enters through
the venting into the heat exchanger, whether by
negative pressures within the installation location or
by strong outside winds.
The manufacturer also highly recommends the use
of a backflow vent damper to minimize the amount of
cold air entering through the exhaust venting when
the water heater is off.

It is the installer’s responsibility to be aware of freezing
issues and take all preventative measures. The manufac-
turer will not be responsible for any damage to the heat
exchanger as a result of freezing.
If you will not be using your heater for a long period of
time:

1. Completely drain the unit of water. Refer to pg. 29.

2. Disconnect power to your heater.

This will keep your unit from freezing and being dam-

aged.