110 & 310

510

Malfunction description

Diagnosis

Red LED

TK-RE02

TM-RE30

N/A

N/A

441

Flow Sensor Failure (Easy-
Link System only)

Check for connection/breakage of
wires and/or debris on the flow sensor
impeller. (Part #402, 717)

Six Times

51

510

Abnormal Gas Solenoid Valve

Check for connection/breakage of
wires (Part #708) and/or burn marks
on the computer board (Part #701).

55

N/A

Abnormal Main Gas Valve

Check for connection/breakage of
wires (Part #708) and/or burn marks
on the computer board (Part #701).

Four Times

61

611

Fan Motor Fault

Check for connection/breakage of
wires, dust buildup in the fan motor
(Part #103) and/or burn marks on the
computer board (Part #701).
Check for frozen/corrosion of connec-
tors (Part #103).

N/A

N/A

651

Flow Adjustment Valve Fault
(Easy-Link System only)

Inspect the flow adjustment valve (Part
#402), for connection/breakage of
wires (Part #718), locked motor drive
due to scale buildup, and/or water
leakage.

One Time

70

701

Computer board Fault

Check for connection/breakage of
wires (Part #714) and/or burn marks
on the computer board (Part #701).
Check the power supply of the water
heater.

Six Times

72

721

False Flame Detection

Check if condensate drain is installed
on the vent collar of the water heater.
Check if there is leaking from heat
exchanger (Part #401).

N/A

74

741

Miscommunication between
water heater and remote
Controller

Check the model type of the remote
controller.
Inspect the connections between the
water heater and remote controller.
Check the power supply of the water
heater.

N/A

N/A

761

Miscommunication in Easy-
Link system

Check if the connections between the
parent unit and the child units are cor-
rect. Refer to pg. 20-22.

Advertising