SPECIFICATIONS

Model

110

310

510

Natural Gas Input
(Operating Range)

Min.: 19,500 BTU/h

Max.: 140,000 BTU/h

Min.: 11,000 BTU/h

Max.: 190,000 BTU/h

Min.: 11,000 BTU/h

Max.: 199,000 BTU/h

Propane Input
(Operating Range)

Min.: 19,500 BTU/h

Max.: 140,000 BTU/h

Min.: 11,000 BTU/h

Max.: 190,000 BTU/h

Min.: 11,000 BTU/h

Max.: 199,000 BTU/h

Gas Connection

3/4” NPT

Water Connections

3/4” NPT

Water Pressure

15 - 150 psi*

Inlet
Pressure

Natural Gas

Min. 5.0” WC, Max. 10.5” WC

Propane

Min. 8.0” WC, Max. 14.0” WC

Manifold
Pressure**

Natural Gas

2.0” WC

2.0” WC

2.0” WC

Propane

2.5” WC

3.7” WC

3.7” WC

Weight

13Kg (28.7 lbs.)

15.7Kg (34.6 lbs.)

Dimensions

520mm(H) x 351mm(W) x 170mm(D)

H20.5” x W13.8” x D6.7”

520mm(H) x 351mm(W) x D216mm(D)

H20.5” x W13.8” x D8.5”

Ignition

Electric Ignition

Electric

Supply

120 VAC, 60 Hz

Consumption

Operation

73.1 W / 0.61 A

87.6 W / 0.73 A

89.8 W / 0.75 A

Standby

6.2 W / 0.05 A

6.2 W / 0.05 A

6.2 W / 0.05 A

Freeze-Protection

111 W / 0.93 A

111 W / 0.93 A

111 W / 0.93 A

* 40 psi or above is recommended for maximum flow.
** The Manifold Pressure is the factory setting and generally should not need adjustment.