Normal operation general, Temperature settings, 510 computer board – John Wood Takagi - 110-310-510 User Manual

Page 25

Advertising
background image

25

NORMAL OPERATION
General

Hot Water temperatures over 52°C
(125°F) can cause severe burns instant-
ly or death from scalding.
The outlet hot water temperature of
the water heater is factory set at 50°C
(122°F).
Feel the water temperature before bath-
ing or showering.

Note:

Flow rate to activate the water heater: 2.8 l/min (0.75 gal-
lon (US) per minute).
Flow rate to keep the water heater running: 1.5 l/min (0.4
gallon (US) per minute).

1. Open a hot
water tap.*

2. Mix cold water
with the hot to get
the correct tem-
perature water.

3. Close the hot
water tap.

* If a remote controller installed, turn the remote controller
ON by pressing the power ON/OFF button on the remote
controller and then set the temperature by pressing the
HOT/COLD buttons before opening a hot water tap. The
temperature is displayed when the remote controller is
turned ON.

Temperature Settings

Without Remote Controller
Depending on the model, there are 4 or 8 temperatures that
you can select from by changing the DIPswitch settings on
the computer board without the remote controller. See the
table below.

Model

Temperatures available

110

45°C

(113°F)

50°C

(122°F)

55°C

(131°F)

60°C

(140°F)

310

510

40°C (104°F) 45°C (113°F) 50°C (122°F) 55°C (131°F)

60°C (140°F) 70°C (158°F) 80°C (176°F) 85°C (185°F)

For detailed DIPswitch settings for each temperature, refer
to the following chart.

The temperature has been preset at the factory to 50°C
(122°F).
If temperatures other than the ones listed above are
required, the remote controller can provide several more
temperature options. Refer to pg. 8 for a list of available
temperatures on the remote controller.
This water heater is an on-demand, tankless water
heater designed to efficiently supply endless hot water
without reference to temperature settings.

DIPswitch Settings For Temperature

110 & 310 Computer board

DIPswitches

510 Computer board

DIPswitches (Right bank)

110 & 310 Models

Temperature Settings

45°C

(113°F)

50°C

(122°F)

DEFAULT

55°C

(131°F)

60°C

(140°F)

Switch

No. 7

OFF

ON

OFF

ON

Switch

No. 8

OFF

OFF

ON

ON

ON

8

7

6

5

4

3

2

1

ON

8

7

6

5

4

3

2

1

ON

8

7

6

5

4

3

2

1

ON

8

7

6

5

4

3

2

1

510 Models

Temperature Settings (Right bank)

40°C

(104°F)

45°C

(113°F)

50°C

(122°F)

DEFAULT

55°C

(131°F)

Switch

No. 4

OFF

OFF

OFF

ON

Switch

No. 5

OFF

ON

OFF

OFF

Switch

No. 6

ON

OFF

OFF

OFF

ON

6

5

4

3

2

1

ON

6

5

4

3

2

1

ON

6

5

4

3

2

1

ON

6

5

4

3

2

1

60°C

(140°F)

70°C

(158°F)

80°C

(176°F)

85°C

(185°F)

Switch

No. 4

OFF

ON

ON

ON

Switch

No. 5

ON

OFF

ON

ON

Switch

No. 6

ON

ON

OFF

ON

ON

6

5

4

3

2

1

ON

6

5

4

3

2

1

ON

6

5

4

3

2

1

ON

6

5

4

3

2

1

Advertising