Mp 101, cont’d, Rack installation – Extron Electronics MP 101 Series User Guide User Manual

Page 14

Advertising
background image

2-6

MP 101 Series • MP 101

MP 101, cont’d

Rack installation

The MP 101 can be rack mounted using either the VersaTools 19"
1U rack shelf (part #60-190-20), basic VersaTools rack shelf
(part #60-604-20), a standard universal 1U rack shelf
(part #60-190-01), or a 1U basic rack shelf (part #60-604-01).

The fi gure below shows the VersaTools rack shelf, and the fi gure
on the following page shows a standard rack shelf. On the
standard rack shelf, there are eight mounting locations at the
front of the shelf and eight at the rear of the shelf.

1.

Remove the rubber feet from the unit, if they were
previously installed.

2.

Mount the unit on the rack shelf, using two 4-40 x 3/16"
screws. These screws go into holes on the underside of the
unit near the left-front and right-rear corners.

3.

Install blank panels (included with part #60-190-xx,
optional with part #60-604-xx) or other units on the rack
shelf.

(2) 4-40 x 3/16"
Screws

Use 2 mounting holes on
opposite corners.

VersaTools Rack Shelf

1/4 Rack Width Front
False Faceplate