Mp 101, cont’d remote control, Remote connector wiring, Remote control options – Extron Electronics MP 101 Series User Guide User Manual

Page 18: All nominal levels are at ±10

Advertising
background image

2-10

MP 101 Series • MP 101

MP 101, cont’d

Remote Control

The wiring and control options described below pertain to all
models in the MP 101 series.

Remote connector wiring

As shown below, Pin 1 is 10 VDC reference voltage. Pin 2 is
volume control DC voltage; range is 0 to 10 V, where 0 V is mute
and 10 V provides maximum volume. Pin 3 is ground.

N

All nominal levels are at ±10%.

REMOTE

10V
VOL/MUTE

1

2

3

GND

10K

2K

MAX

2

3

1

MIN

POWER
12V

0.5A MAX

MIC

INPUT

REMOTE

VOL/MUTE

MP 101

MIC TO LINE
PREAMPLIFIER

10V

LINE

OUTPUT

MUTE

Remote control options

The MP 101 has three remote control options:

1.

The Extron VCM 100 volume/mute controller and
VC 50

volume controller use a 10 k ohm potentiometer as

the main method for controlling volume levels.

The VCM 100 includes an illuminated Mute button and
operates in sync with the MP 101 AAP.

2.

The Extron MLA-VC10 converts RS-232 serial command
to 0~10 volt variable DC for volume control.

3.

Generic volume/mute controllers are standard 10 k ohm
potentiometers.

Advertising