Extron Electronics MP 101 Series User Guide User Manual

Page 28

Advertising
background image

4-3

MP 101 Series • MP 101 D

N

Do not tin the stripped power supply leads before

installing the captive screw connector. Tinned wires are
not as secure in the captive screw connectors and could
pull out.

W

The two power cord wires must be kept separate while

the power supply is plugged in. Remove power before
continuing.

Audio output (line level)

b

Phantom power switch

— Provides switchable 48 volt phantom

power for condenser microphones.

c

Line

Output

— A 3-pin, captive screw connector outputs to

audio mixers, amps switchers, or other non-microphone audio
equipment.

Tip

Sleeve

NO Ground Here

CAUTION

For unbalanced audio, connect the sleeve(s)
to the ground.

DO NOT

connect the sleeve(s)

to the negative (-) contact.

(5 mm) MAX

Captive Screw

Connector stripping

3/16"

Tip

Sleeve

Ring

d

Low Cut fi lter switch

— Provides low cut fi ltering to remove

wind and “table rumble” noise.

Remote connection

e

Remote

— An optional 3-pin, captive screw connector allows

a wall mounted audio controller or MediaLink product to
remotely control volume and mute levels for the MP 101
unit. See “Remote Control”, later in this chapter, for more
information.

Advertising