Adjusting the mp 101 d, Mounting the mp 101 d – Extron Electronics MP 101 Series User Guide User Manual

Page 30

Advertising
background image

4-5

MP 101 Series • MP 101 D

3-pin

Female

2

3

1

Adjusting the MP 101 D

Adjustment options for the MP 101 D are located on its rear
panel (see “Rear Panel Features” in this chapter for details).
Therefore, you must perform these adjustments before
mounting into a wall.

To adjust the MP 101 D, do the following:

1.

If using a condenser microphone, set the Phantom power
switch to the “on” position.

If using a dynamic microphone, set the Phantom power
switch to the “off” position.

2.

When using the microphone for voice audio, fl ip the Low
Cut switch to “on” to reduce wind and “table rumble”
noise.

When using the microphone for music audio, set the Low
Cut switch to “off” to preserve the optimum sound quality.

3.

Set the Mic Gain potentiometer by saying a few words into
the microphone and adjusting for the maximum sound
level that is free of distortion.

N

If there is a remote control connection, unplug it while

adjusting the Mic Gain potentiometer. Replace the remote
control when fi nished.

If there is minimal distortion, but greater volume is
required, turn the Mic Gain potentiometer clockwise
(towards the 75 dB mark) to increase the volume, but not
past the point where distortion occurs.

Mounting the MP 101 D

The MP 101 D provides the same features as the other
MP 101 models in a convenient, Decora

style wallplate.

Advertising