4

.

Repeat steps 1 through 3 to mount any other AAPs. Cover
any openings in the faceplate with blank plates (provided).

5.

If it was not done previously, adjust the MP 101 AAP from
its rear panel. See the previous section, “Adjusting the
MP 101 AAP” for detailed instructions.

6.

Pretest the MP 101 AAP before fi nal mounting of the
faceplate.

7.

Perform the fi nal mount by attaching the cabled device
faceplate or AAP wallplate into a wall or piece of
furniture. For detailed installation information, refer to the
installation guide shipped with the faceplate.

Remote Control

The wiring and control options described below pertain to all
models in the MP 101 series.

Remote connector wiring

Pin 1

is 10 VDC reference voltage. Pin 2 is volume control DC

voltage; range is 0 to 10 V, where 0 V is mute and 10 V provides
maximum volume. Pin 3 is ground.

N

All nominal levels are at ±10%.

REMOTE

10V
VOL/MUTE

1

2

3

GND

10K

2K

MAX

2

3

1

MIN

MUTE