Specifications

225

Position range

±8 divisions away from the center of the screen

Attenuation factor

X1, X10, X100, X1000

Channel common

mode rejection

100:1 at 60 Hz

20:1 at 10 MHz

[1]

Lower frequency

limit, AC coupled

≤ 5 Hz at BNC

≤ 1 Hz when using a 10X passive probe

Channel to

channel crosstalk

≥ 100:1 at 1 MHz

≥ 100:1 at 10 MHz

[1]

Input Impedance

1

MΩ ||18 pF

Maximum input

400 V

pk

@1 M

Ω

Differential delay

±150 ps when vertical scale and coupling

settings are identical

[1]

Bandwidth reduced to 6 MHz with a 1X probe.

Horizontal system

Time base range

(1-2-5 step)

2 ns/div to 50 s/div

Modes

Main, Delayed, Roll and X-Y

Time base accuracy

± 0.01 %

Input of X-Y mode

Channel 1 is the horizontal X-axis input

Channel 2 is the vertical Y-axis input

Bandwidth of X-Y mode

60 MHz:

2540B, 2540B-GEN

100 MHz:

2542B, 2542B-GEN

Phase error of X-Y mode

± 3°

Advertising